Duct Checker - Software helps to calculate the size of the duct, the air outlet according to the static pressure loss.
Download Duct Checker 170 (Latest): https://secufiles.com/mtUt/Duct_Checker_170.exe
○ Application of Duct Checker
- Pipe dimensions are easy to determine by the constant pressure method
- The friction reference unit loses resistance, the standard wind speed can be set freely
- Display the actual loss resistance and wind speed etc in decision tube
○ Summary of Duct Checker
Pipe sizing methods, constant pressure method, a collection method, total pressure method, which has the constant velocity method, as the most widely used method , the constant pressure method (equal friction loss method). (All pipe sizing methods use the same value on the friction loss per 1m tube) would normally be determined by a pipe Toka flow chart designed for the rules of slip, the use of these programs.
Duct Checker operating environment
Operating System: Windows 9X, Windows NT 4, Windows 2000, Windows XP, Windows 7, Windows 10.
○ Go to the Duct Checker formula input
When entering the airflow rate, you can enter mathematical expressions.
exp.1 1500 + 1500 → 3000
exp.2 500 * 3 + 1000 → 2500
You can only use four arithmetic operations (+, -, *, /), powers (^), etc.
SIN, COS, TAN, ASIN, ACOS, ATAN, LOG 10, LN, EXP, SQR, SQRT
Can be used.
(Note: angle in degrees)
exp.3 ATAN (1) → 45
exp.4 LOG 10 (1000) → 3
Variables can also be used. Variables begin with the letter "A ... Z _", followed by alphabetic characters, underscores, and numbers. Two-byte codes (Kanji or Hiragana) cannot be used.
(Note: Upper and lower case letters are not distinguished.)
exp.5 ABC = 150 → 150
exp.6 ABC * 5 → 750
exp.7 PI → 3.14159265358979
○ Duct Checker start option
[/ eng] Required in English.
[/ jpn] Starts with Japanese mode.
(In the absence of the above option, it starts with Japanese for Japanese OS and English mode for other language OS)
Duct Checker Change History
Ver 1.70 | 08/31/2014 Some bug fixes |
Ver 1.61 | 3/2014 Fixed a bug causing an error depending on the OS language settings |
Ver1.55 | 2003/04/21 For messages other than Japanese, we sent messages in English. The upper limit value of the additional aspect ratio of the boot options (/ eng, / jpn) can be set. Change program setting |
Ver1.53 | 2003/04/21 The wind speed at the equivalent diameter is shown. |
Ver1.51 | 2002/04/12 We made it show the equivalent diameter of the angle pipe. Some bug fixes |
Ver 1.50 | 2002/03/10 Change so you can change the size of the revision window so that you can store a number of selected criteria templates. Some bug fixes |
Ver 1.39c | 06/01 2001 Fixed a bug causing an error when launching on Windows 2000 |
Ver 1.39 b | 2001/03/20 trigonometric functions sine (), cos (), tan (), asine (), acos (), with the home change unit change using atane () in radians (RAD) degrees from (DEG), Change the reference URL |
Ver 1.39 a | Additional defect adjustment variable pi (circle rate) causes error when trying to re-enter the air mass at the time of the static pressure test |
Ver 1.39 | Fixed issue displaying detailed data not being deleted even when changing air volume value when air outlet / intake port was selected |
Ver 1.38b | Fixed display error not changing even when changing the setting condition when selecting the exhaust / intake port |
Ver 1.38 a | Correct errors when checking pipes When a tube size is selected Move position with left mouse click, change detail data to change dynamic display |
Ver 1.38 | Variables, formulas can be entered. Some other tweaks |
Ver 1.37 | Fixed an error occurring when entering a small air quantity |
Ver 1.36 | Fixed algorithm error |
Ver 1.35 | Change the pipe test tab so that you can test on the main tab. Some bug fixes |
Ver 1.34 | Added display option at the top Add current monitor on home screen. |
Ver 1.33 | Correct the relative error in the aperture ratio display |
Ver 1.32 | Error correction related to operation |
Ver 1.31 | Fixed bug with clipboard copy |
Ver1.3 | I resized the model a bit more compact so I could test the static pressure. Additional function supporting blowing / suction port selection |
Ver 1.11 | Fixed dynamic pressure calculation error |
Ver 1.1 | Internal algorithm changed |
Ver 1.0 | The first published version |
Download Duct Checker 170 (Latest): https://secufiles.com/qG2U/Duct_Checker_170.rar